Refractometer Calculator

Convert refractometer Brix readings to original gravity, alcohol-corrected final gravity and ABV, with Sean Terrill's cubic or linear formula.

To read final gravity with a refractometer, divide both Brix readings by the wort correction factor, usually 1.04, then correct for alcohol with Sean Terrill's formula. Wort that read 13.0 °Bx and now reads 6.5 °Bx is at about 1.012, not the 1.025 the raw reading suggests: about 5.2% ABV.

Reviewed by Diego Santiago, Professional Brewer

Formula

Wort before pitching the yeast

Fermenting or finished beer

1.04 if you have not measured your own

Original gravity1.050SGCurrent gravity (corrected for alcohol)1.012SGAlcohol by volume5.05% ABVApparent attenuation76%

Results are estimates provided "as is," for informational and planning purposes only, without warranties of any kind. Check them before you rely on them: you are responsible for decisions about your beer and equipment, including pressure and carbonation levels, the pressure ratings of your kegs and fittings, and any alcohol content you declare. Use of this calculator is subject to our Terms and Conditions.

Plan recipes, track every batch and keep all your brewing numbers in one place. Foambyte is free to start.

Start Free

How refractometer readings are corrected

A refractometer needs only a few drops of wort, so many brewers use it on brew day and during fermentation. Before fermentation, the reading converts directly to gravity. First divide it by the wort correction factor kk:

R=°BxkR = \frac{\text{°Bx}}{k}

The calculator then converts RiR_i, the corrected original reading, to specific gravity with the same Brix conversion as Foambyte’s gravity converter.

Once fermentation starts, alcohol distorts the reading. Sean Terrill fitted two formulas to measured readings, both using the corrected original reading RiR_i and the corrected current reading RfR_f. The cubic one:

FG=1−0.0044993 Ri+0.011774 Rf+0.00027581 Ri2−0.0012717 Rf2−0.0000072800 Ri3+0.000063293 Rf3\begin{aligned} FG = {} & 1 - 0.0044993\,R_i + 0.011774\,R_f \\ & + 0.00027581\,R_i^2 - 0.0012717\,R_f^2 \\ & - 0.0000072800\,R_i^3 + 0.000063293\,R_f^3 \end{aligned}

and the linear one:

FG=1−0.00085683 Ri+0.0034941 RfFG = 1 - 0.00085683\,R_i + 0.0034941\,R_f

ABV is then (OG−FG)×131.25(OG - FG) \times 131.25, and apparent attenuation is the share of the original gravity points that is gone.

For example, wort that read 13.0 °Bx before fermentation has an original gravity of 1.051. If the beer now reads 6.5 °Bx, the cubic formula gives a gravity of 1.012: about 5.2% ABV and 77% apparent attenuation. The uncorrected reading would suggest about 1.025.

Inside Foambyte, you record gravity readings for each batch in the unit you prefer and follow fermentation on the batch chart.

Reference table

Corrected gravity (SG) by original reading (rows) and current reading (columns) in °Bx, Terrill cubic formula with a wort correction factor of 1.04
Original \ current °Bx4567891012
10 °Bx1.0061.0101.0141.0171.0201.023——
12 °Bx1.0041.0081.0111.0151.0181.0211.026—
14 °Bx1.0021.0061.0091.0131.0161.0191.0241.035
16 °Bx1.0001.0041.0071.0101.0141.0171.0211.033
18 °Bx0.9971.0011.0051.0081.0111.0151.0191.031
20 °Bx0.9940.9981.0011.0051.0081.0111.0161.027
22 °Bx0.9890.9940.9971.0001.0031.0071.0111.023
24 °Bx0.9840.9880.9910.9950.9981.0011.0051.017

Sources

  1. Sean Terrill. “Refractometer FG Results”, seanterrill.com, 2011. Cubic and linear final gravity correlations and the 1.04 default wort correction factor.

Frequently asked questions

Why does a refractometer read wrong after fermentation starts?

A refractometer measures how much the sample bends light. Sugar and alcohol both bend light, but alcohol makes the sample lighter rather than denser, so once yeast turns sugar into alcohol the Brix reading no longer matches the gravity. The correction uses the original reading to estimate how much alcohol there is and removes its effect.

What is the wort correction factor?

Refractometers are calibrated for sugar dissolved in water, and wort contains other dissolved substances that bend light slightly differently. The wort correction factor divides each reading to account for that. Sean Terrill's correlations were fitted with 1.04, the usual default; you can measure your own by comparing refractometer and hydrometer readings of the same unfermented wort.

Should I use the cubic or the linear formula?

Both come from Sean Terrill's analysis of 68 sets of readings from several brewers. In his results the linear formula was slightly more accurate on average and the cubic slightly more precise. In his data, both were about as accurate as a typical homebrew hydrometer.

How accurate is a corrected refractometer reading?

For typical beers it is usually within a few gravity points of a hydrometer. Terrill notes that it fails for beers below about 50% real attenuation, such as some sweet stouts. To confirm a final gravity before packaging, measure it with a hydrometer.

Can I use this for cider or mead?

The correction was fitted to beer worts. Cider and mead musts have different sugars and often reach higher alcohol, so the results are less reliable there.