Hydrometer Temperature Correction

Correct a hydrometer reading taken at the wrong temperature to your hydrometer's calibration temperature, in °C or °F.

A hydrometer reads low when the sample is warmer than its calibration temperature, because warm liquid is less dense. The correction scales the reading by the change in the density of water between the two temperatures. A reading of 1.048 at 30 °C on a hydrometer calibrated at 20 °C is really about 1.051.

Reviewed by Diego Santiago, Professional Brewer

Units

Gravity read at the sample temperature

Temperature of the wort or beer in the test jar

Printed on the hydrometer, often 20 °C (68 °F) or 15.6 °C (60 °F)

Corrected gravity1.053SGCorrection+2.7points

Results are estimates provided "as is," for informational and planning purposes only, without warranties of any kind. Check them before you rely on them: you are responsible for decisions about your beer and equipment, including pressure and carbonation levels, the pressure ratings of your kegs and fittings, and any alcohol content you declare. Use of this calculator is subject to our Terms and Conditions.

Plan recipes, track every batch and keep all your brewing numbers in one place. Foambyte is free to start.

Start Free

How the correction works

A hydrometer compares the density of the sample with the density of water at its calibration temperature. Wort and beer expand with temperature at nearly the same rate as water, so the calculator scales the reading by how much the density of water changes between the two temperatures:

SGc=SGr×ρ(Tc)ρ(Ts)SG_c = SG_r \times \frac{\rho(T_c)}{\rho(T_s)}

where SGrSG_r is the reading, TsT_s the sample temperature, TcT_c the calibration temperature and ρ\rho the density of water. The density of water comes from the formula recommended by Tanaka and colleagues for 0 to 40 °C:

ρ(t)=a5[1−(t+a1)2 (t+a2)a3 (t+a4)]\rho(t) = a_5 \left[1 - \frac{(t + a_1)^2\,(t + a_2)}{a_3\,(t + a_4)}\right]

with tt in °C, a1=−3.983035a_1 = -3.983035, a2=301.797a_2 = 301.797, a3=522528.9a_3 = 522528.9, a4=69.34881a_4 = 69.34881 and a5=999.97495a_5 = 999.97495 kg/m³.

For example, a reading of 1.048 at 30 °C (86 °F) with a hydrometer calibrated at 20 °C (68 °F) corrects to 1.051. With a 15.6 °C (60 °F) hydrometer, the same reading corrects to about 1.052.

The correction ignores the small expansion of the hydrometer’s own glass, and dissolved CO₂ or bubbles on the hydrometer make it read high. Degas beer samples and spin the hydrometer to dislodge bubbles before you read it.

Inside Foambyte, you record each batch’s gravity readings with their temperature and follow fermentation on the batch chart.

Reference table

Gravity points to add to a 1.050 reading by sample temperature (rows) and hydrometer calibration temperature (columns); negative values are subtracted
Sample temperature60 °F (15.6 °C) hydrometer68 °F (20 °C) hydrometer
50 °F (10.0 °C)-0.7-1.6
55 °F (12.8 °C)-0.4-1.3
60 °F (15.6 °C)0.0-0.9
65 °F (18.3 °C)0.5-0.3
68 °F (20.0 °C)0.90.0
70 °F (21.1 °C)1.10.2
75 °F (23.9 °C)1.80.9
80 °F (26.7 °C)2.51.7
85 °F (29.4 °C)3.42.5
90 °F (32.2 °C)4.33.4
95 °F (35.0 °C)5.34.4
100 °F (37.8 °C)6.35.5

Sources

  1. Masami Tanaka, Georges Girard, Richard Davis, Arturo Peuto and Neville Bignell. “Recommended table for the density of water between 0 °C and 40 °C based on recent experimental reports”, Metrologia, 2001. Density of water as a function of temperature.

Frequently asked questions

Why does temperature change a hydrometer reading?

Liquids expand as they warm, so warm wort is less dense and the hydrometer sinks deeper and reads low. Cold wort is denser and reads high. The hydrometer is only exact at the temperature it was calibrated for.

What is my hydrometer's calibration temperature?

It is usually printed on the scale or the box. Common calibration temperatures are 20 °C (68 °F) and 15.6 °C (60 °F).

Can I measure hot wort?

This calculator accepts samples up to 40 °C (104 °F), the range of the water density formula it uses. Hotter samples also risk cracking the test jar or the hydrometer, and the correction becomes less accurate. Cool the sample first, for example in a covered jar in cold water.

How large is the correction?

Small near the calibration temperature and larger as the gap grows. With a 20 °C hydrometer, a 1.050 reading at 25 °C becomes about 1.051, and at 35 °C about 1.054.

Does this work for refractometers?

No. Most refractometers correct for temperature automatically (ATC). For refractometer readings during or after fermentation, use the refractometer calculator.